Ray 02 standing on its black backboard with copper trace lines, seen from below: the inlet union at the top, the octagonal electrode pod marked ray 02 at the centre.

Ray 02Mid-flow

Copper and silver ionisation for commercial water systems.

  • Treats 5–150 L/min on 2 inch pipework, up to 9 bar
  • Ultrasonic flow measurement, dosing down to parts per billion
  • Live status over LAN or LTE, BMS compatible
  • Electrode pod serviced on site in one visit
5–150 L/min
Flow range

Sized for whole buildings, between Ray 01 and Ray 03.

9 bar
Max operating pressure

Headroom for mains-fed commercial systems.

2 in
Pipe connection

Fits inline on standard commercial pipework.

LAN · LTE
Remote monitoring

Live status and settings changed without a visit.

Why Ray 02

Treats the whole building. Fits on one wall.

Copper and silver ionisation that keeps Legionella, Pseudomonas and other harmful waterborne bacteria under control, from one wall-mounted unit.

The complete Ray 02 system on a wall: control panel on the left, unit on its backboard on the right.

Lower cost to own

Designed for efficient manufacture and a lean supply chain, Ray 02 brings site-wide copper and silver treatment within reach of more projects. Optimised dosing and in-house maintenance keep running costs down.

The Ray 02 electrode insert lifted out of the pod, silver bars in the upper window and copper in the lower one.

Maintained by your own engineers

The electrode chamber is easy to reach: undo two unions and the pod lifts out whole, then the insert slides free. For the first time, distributors can maintain a ProEconomy system themselves.

An engineer holding a tablet that shows live Ray 02 flow and ion output trends.

Smart, connected dosing

Every unit is remotely accessible, so settings change on the fly as water conditions change. Ray 02 talks directly to tetras cloud, and together they optimise dosing.

How it works

Water in at the top. Protected water out at the bottom.

Ray 02 is mounted vertically and treats water as it passes through. Follow one litre through the unit.

Section through Ray 02, shown vertically. Water enters at the top union, passes the silver electrodes inside the pod, then the longer copper electrodes, past the flow sensor and out through the lower union.
1Inlet union2 in, flow top to bottom
2Silver electrodes2 × Ag bars
4Copper electrodes2 × Cu bars
5Ultrasonic flow sensorReads flow for the PLC
3
6Outlet unionTreated water to the building
Callouts, top to bottom: 1 inlet union, 2 silver electrodes, 3 bracket along the removable electrode pod, 4 copper electrodes, 5 ultrasonic flow sensor, 6 outlet union. Animated lines show water running through the unit. The numbers match the steps alongside.
  1. Inlet

    Water enters from the top.

    Ray 02 fits inline on 2 inch pipework and is mounted vertically, so water always flows top to bottom.

    2 in5–150 L/min≤ 9 bar≤ 30 °C
  2. Silver

    Silver ions are released.

    Low-voltage DC passes across two silver bars in the upper part of the pod and releases Ag⁺ ions into the stream.

    2 × Ag bars0.340 kg per bar12 V · 0.9 A max
  3. Service

    Serviced in place.

    With the system on by-pass, the pod lifts out between its two unions for the bars to be cleaned or replaced.

    Monthly visitNo specialist contractorReplace below 10 % material
  4. Copper

    Then copper ions.

    Two copper bars below release Cu²⁺ ions. Together, copper and silver ions control Legionella, Pseudomonas and other disease-causing bacteria.

    2 × Cu bars0.620 kg per bar48 V · 3 A maxBPR-compliant metals
  5. Measure

    Flow is measured continuously.

    An ultrasonic sensor reads the flow and the PLC matches ion output to it, down to parts per billion. No flow, no dosing.

    Ultrasonic sensingPLC dosing controlBMS compatible
  6. Distribute

    Protection travels with the water.

    Ions leave with the water and reach the whole system, including little-used outlets.

    Whole-system residualNo COSHH chemicals
Ray 02 · User manual v1.3, section 1.3

Exploded view and parts list

Exploded line drawing of Ray 02 showing the pipe sections, unions, electrode pod inserts, outer sleeve, backboard and fixings, numbered 1 to 27 to match the parts list.
1a
2″ grey PVC pipe, 160.5 mm
1b
2″ grey PVC pipe, 435 mm
1c
2″ grey PVC pipe, 330 mm
2
2″ plain PVC union, EPDM O-ring
3
2″ plain : threaded PVC socket
4
2″ plain socket : male PVC adaptor
5
2″ plastic pipe clip (PP)
6
Spacer block for pipe clip
7
Thread insert, Multisert, M6
8
Back board, CNC machined
9
Back board screen printing
10
Sealing washer, 6–16 mm
11
Screw, M6 × 30 mm, socket cap
12
Ring terminal, M6
13
5-core flex cable, 1.0 mm²
14
Custom cable clip
15
Outer sleeve
16
Upper insert A
17
Upper insert B
18
Lower insert
19
Ultrasonic sensor slot
20
Power connector housing
21
Self-countersunk screws
22
Self-tapping screw, 3.9 × 16 mm
23
Self-tapping screw, 4.2 × 9.5 mm
24
Hexagon nut, M6 A4
25
Ultrasonic flow sensor
26
5-pole connector, male
27
5-pole connector, female
Electrode access

The insert lifts straight out. And clicks straight back in.

A removal system built for Ray 02. Scroll to see the electrode insert come out of the unit.

Insert animationFrame sequence to be added
  1. 01Open the podPod off the backboard, housing removed.
  2. 02Lift the assemblyClamp released, the electrode assembly comes free.
  3. 03Slide the bars outCap off, copper and silver bars slide out for cleaning or replacement.
Installation and maintenance

Engineer-friendly design.

Installation

Plug and play. Arrives assembled on its backboard, connects with keyed plugs.

Drilling the fixing holes for the Ray 02 backboard.
Maintenance

Simple to service. The pod lifts out whole, done in one visit.

Engineer reading the bar voltage on the pod with a multimeter.
System overview

The unit in detail.

Select a point on the drawing to see its size and material.

400 mm500 mm200 mm1040 mm190 mm125 mm RAY 02 · SYSTEM · DIMENSIONS IN MM
Drawing of the Ray 02 control panel, 500 by 400 by 200 millimetres, and the unit on its backboard, 1040 millimetres tall, 190 wide and 125 deep. Points to select: control panel, power connector, inlet, upper union, electrode pod, ultrasonic sensor slot and outlet.

Hydraulics and electrodes

Flow rate
5–150 L/min
Pipe size
2 inch
Max operating pressure
9 bar
Electrode bars
2 silver / 2 copper
Weight of electrodes
Ag 0.340 kgCu 0.620 kg per bar
Copper and silver purity
99.9 %BPR compliant
Cold water applications
30 °C max
Main unit
1040 × 190 × 125 mmL × W × H
Control panel
500 × 400 × 200 mmH × W × D
Unit weight
8 kg
Control panel weight
12.5 kg

Control and electronics

Flow sensing
Ultrasonic
Dosing control
PLC, flow-proportional
Voltage and power
230 V AC at 5 A max
Ionisation output, copper
48 V at 3 A max
Ionisation output, silver
12 V at 0.9 A max
Remote access
IncludedLAN and LTE
Building management
Modbus BMS ready
Mounting
Wall, single backboard

A control panel and ultrasonic flow sensor dose by flow rate, with remote access for real-time monitoring.

Applications

Sized for the whole building. Where Ray 02 fits.

For sites with 5 to 150 L/min of flow on 2 inch pipework.

  • Hotels

    Guest rooms, kitchens and spa areas on one supply.

  • Offices

    Multi-floor buildings with long, little-used runs.

  • Leisure and sports centres

    Showers, changing rooms and pool plant.

  • Mid-sized hospitals

    Wards and clinics where water safety is critical.

Remote monitoring

Every Ray 02 reports to tetras.

The control panel connects over LAN or LTE, so whoever is responsible for the water system can see what the unit is doing without a site visit.

Interface preview with sample data.
Ray 02Control panelLAN · LTEtetras
Product family

Three units, sized by flow.

The same fields in the same order for every model. Ray 02 covers the middle of the range. Each model is modular, so several units can run side by side as a site grows.

Ray 01, Ray 02 and Ray 03 specifications compared
Specification
Ray 01Low-flow
Ray 02Mid-flow
Ray 03High-flow
Hydraulics
Flow rate1–22 L/min5–150 L/min150–500 L/min
Pipe size1½ in2 in4 in
Max operating pressure6 bar9 bar9 bar
Max water temperature30 °C30 °C30 °C
Electrodes
Silver bars2 × 0.021 kg2 × 0.340 kg2 × 0.340 kg
Copper bars2 × 0.201 kg2 × 0.620 kg10 × 0.620 kg
Electrode materialBPR-compliant Cu, AgBPR-compliant Cu, AgBPR-compliant Cu, Ag
Control
Flow sensingFlow switchUltrasonicUltrasonic
Dosing controlDigital control boxPLCPLC
Remote monitoringNot availableLAN and LTELAN and LTE
BMS integrationNot availableYesYes
Contact

Request more information. We'll come back to you.

Tell us what you need and the right person will reply.

Prefer to talk? Call +44 (0)1525 854 111 or email sales@proeconomy.com

I would like

* Required

ProEconomy Ltd · Ray SeriesRay 02 mid-flow copper and silver ionisation

ProEconomy's reputation speaks volumes and the Orca system is highly regarded by those who have installed it.

 
 
 
 
 
 
 
Tetras
Translate

Book a FREE Water Management System Demo!