Ray 03 on its black backboard with copper trace lines: 4 inch PVC pipework, two unions and the electrode pod marked ray 03.

Ray 03High-flow

Copper and silver ionisation for large buildings and campuses.

  • Treats 150–500 L/min on 4 inch pipework, up to 9 bar
  • Ultrasonic flow measurement, dosing down to parts per billion
  • Live status over LAN or LTE, BMS compatible
  • Electrode pod serviced on site in one visit
150–500 L/min
Flow range

Sized for large buildings and campuses, the top of the range.

9 bar
Max operating pressure

Headroom for mains-fed commercial systems.

4 in
Pipe connection

Fits inline on large commercial pipework.

LAN · LTE
Remote monitoring

Live status and settings changed without a visit.

Why Ray 03

For very high flow rates.Scaled to the site.

Copper and silver ionisation that keeps Legionella, Pseudomonas and other harmful waterborne bacteria under control, from one wall-mounted unit.

Ray 03 mounted on a wall beside its control panel.

For very high flow rates

Ray 03 treats 150 to 500 L/min, for large hospitals, universities, airports and industrial sites.

The Ray 03 electrode insert on its service stand, with copper bars and a silver bar held in white clips.

Twelve electrodes in one pod

Ten copper bars and two silver bars in a single pod carry the ion output that high flows need.

Three Ray 03 units mounted side by side on a wall.

Scale to any site

Run several Ray 03 units side by side to treat hundreds of thousands of litres per hour, adding capacity as the site grows.

How it works

Water in at the top. Protected water out at the bottom.

Ray 03 is mounted vertically and treats water as it passes through. Follow one litre through the unit.

Section through Ray 03 on its backboard, shown vertically. Water enters at the top, passes the copper and silver bars inside the electrode pod and leaves at the bottom.
1Inlet4 in, flow top to bottom
2Ultrasonic sensorMeasures the flow
3Electrode pod10 × Cu, 2 × Ag bars
4Lower unionPod lifts out for service
5OutletTreated water to the building
Callouts, top to bottom: 1 inlet, 2 ultrasonic sensor, 3 electrode pod, 4 lower union, 5 outlet. Animated lines show water running through the unit. The numbers match the steps alongside.
  1. Inlet

    Water enters from the top.

    Ray 03 fits inline on 4 inch pipework and is mounted vertically, so water always flows top to bottom.

    4 in150–500 L/min≤ 9 bar≤ 30 °C
  2. Measure

    Flow is measured continuously.

    An ultrasonic sensor reads the flow and the PLC in the control panel matches ion output to it. No flow, no dosing.

    Ultrasonic sensingPLC dosing controlLAN · LTEBMS compatible
  3. Ionise

    Copper and silver ions are released.

    Low-voltage DC passes across ten copper bars and two silver bars in the pod, releasing Cu²⁺ and Ag⁺ ions. Together they control Legionella, Pseudomonas and other disease-causing bacteria.

    10 × Cu bars2 × Ag bars48 V · 9.5 A max12 V · 2.5 A max
  4. Service

    Serviced in place.

    With the system on by-pass, the pod lifts out between its two unions so the bars can be inspected, cleaned or replaced.

    Pod lifts out wholeNo specialist contractor
  5. Outlet

    Protection travels with the water.

    Ions leave with the water and reach the whole system, including little-used outlets.

    Whole-system residualNo COSHH chemicals
Inside the pod

Twelve bars in one pod. Ten copper, two silver.

The copper and silver bars set the ion output that high flows need. Scroll to see inside the Ray 03 pod.

Insert animationFrame sequence to be added
  1. 01The electrode podThe pod sits inline and lifts out as one piece.
  2. 02Sleeve offWith the outer sleeve removed, the insert and its bars are exposed.
  3. 03Ten copper, two silverTwelve bars on one insert, for the ion output of a high-flow system.
Installation and maintenance

Engineer-friendly design.

Installation

Plug and play. Keyed connectors, from the unit to the panel.

Two engineers lifting Ray 03 onto the wall.
Maintenance

Simple to service. The pod comes out between two unions.

Engineer measuring the electrode voltage on Ray 03 with a multimeter.
System overview

The unit in detail.

Select a point on the drawing to see its size and material.

1558 mm500 × 400 × 200 mm RAY 03 · UNIT · DIMENSIONS IN MM
Drawing of Ray 03 on its backboard, 1558 millimetres long, with its 500 by 400 by 200 millimetre control panel beside it. Points to select: control panel, power connector housing, inlet, upper union, electrode pod, electrode insert, ultrasonic sensor and outlet.

Hydraulics and electrodes

Flow rate
150–500 L/min
Pipe size
4 in
Max operating pressure
9 bar
Electrode bars
10 copper / 2 silver
Weight of electrodes
Cu 0.620 kgAg 0.340 kg per bar
Copper and silver purity
99.99 %BPR compliant
Cold water applications
30 °C max
Main unit
1558 × 272 × 208 mmL × W × H
Control panel
500 × 400 × 200 mmH × W × D
Unit weight
17 kg
Control panel weight
12.5 kg

Control and electronics

Flow sensing
Ultrasonic flow sensor
Dosing control
PLC
Voltage and power
230 V AC at 5 A max
Ionisation output
Cu 48 V at 9.5 A maxAg 12 V at 2.5 A max
Remote access
LAN and LTEBMS compatible
Mounting
Wall, backboard and panel

The ultrasonic sensor measures flow continuously and the PLC matches copper and silver output to it; status and faults report over LAN or LTE.

Applications

Sized for the largest sites. Where Ray 03 fits.

For sites with 150 to 500 L/min of flow on 4 inch pipework.

  • Large hotels and resorts

    Hundreds of rooms, kitchens and leisure on one supply.

  • Universities and campuses

    Many buildings and long runs from one plant room.

  • Airports and industrial sites

    High, variable demand around the clock.

  • Large hospitals

    Whole estates where water safety is critical.

Remote monitoring

Every Ray 03 reports to tetras.

The control panel connects over LAN or LTE, so whoever is responsible for the water system can see what the unit is doing without a site visit.

Interface preview with sample data.
Ray 03Control panelLAN · LTEtetras
Product family

Three units, sized by flow.

The same fields in the same order for every model. Ray 03 covers the top of the range. Each model is modular, so several units can run side by side as a site grows.

Ray 01, Ray 03 and Ray 03 specifications compared
Specification
Ray 01Low-flow
Ray 02Mid-flow
Ray 03High-flow
Hydraulics
Flow rate1–22 L/min5–150 L/min150–500 L/min
Pipe size1½ in2 in4 in
Max operating pressure6 bar9 bar9 bar
Max water temperature30 °C30 °C30 °C
Electrodes
Silver bars2 × 0.021 kg2 × 0.340 kg2 × 0.340 kg
Copper bars2 × 0.201 kg2 × 0.620 kg10 × 0.620 kg
Electrode materialBPR-compliant Cu, AgBPR-compliant Cu, AgBPR-compliant Cu, Ag
Control
Flow sensingFlow switchUltrasonicUltrasonic
Dosing controlDigital control boxPLCPLC
Remote monitoringNot availableLAN and LTELAN and LTE
BMS integrationNot availableYesYes
Ray Series

Explore other Ray products.

Contact

Request more information. We'll come back to you.

Tell us what you need and the right person will reply.

Prefer to talk? Call +44 (0)1525 854 111 or email sales@proeconomy.com

I would like

* Required

ProEconomy Ltd · Ray SeriesRay 03 high-flow copper and silver ionisation

ProEconomy's reputation speaks volumes and the Orca system is highly regarded by those who have installed it.

 
 
 
 
 
 
 
Tetras
Translate

Book a FREE Water Management System Demo!