NEXT GENERATION
COPPER & SILVER
WATER TREATMENT
A commercial-grade range of copper & silver ionisation systems, purpose-built for low, mid and high-flow applications.
The Ray series redefines water treatment with three flow-optimised units built for commercial performance. Designed to protect everything from single outlets to full distribution systems, each compact model delivers precise copper-silver ionisation with a premium, user-centred design.
Ray Series Brochure DownloadNext-gen water treatment, designed to lower cost, easier to install, simpler to maintain, and easier to specify.
-
Easy to install. Quick to fit, simple to service.
-
Compact. Three purpose-built units for low, mid and high flow.
-
Cost-efficient. Efficient manufacturing, high quality at a lower cost.
-
Considered design. A premium, modern form made around the user.
Select your Ray system. One range, three flows.
Choose the model that matches your flow rate. Every Ray is modular: several units of the same model can run side by side, so treatment scales with the site, up to hundreds of thousands of litres per hour.
| Specification | |||
|---|---|---|---|
| Hydraulics | |||
| Flow rate | 1–22 L/min | 5–150 L/min | 150–500 L/min |
| Pipe size | 1½ in | 2 in | 4 in |
| Max operating pressure | 6 bar | 9 bar | 9 bar |
| Max water temperature | 30 °C | 30 °C | 30 °C |
| Electrodes | |||
| Silver bars | 2 × 0.021 kg | 2 × 0.340 kg | 2 × 0.340 kg |
| Copper bars | 2 × 0.201 kg | 2 × 0.620 kg | 10 × 0.620 kg |
| Electrode material | BPR-compliant Cu, Ag | BPR-compliant Cu, Ag | BPR-compliant Cu, Ag |
| Control | |||
| Flow sensing | Flow switch | Ultrasonic | Ultrasonic |
| Dosing control | Digital control box | PLC | PLC |
| Remote monitoring | Not available | LAN and LTE | LAN and LTE |
| BMS integration | Not available | Yes | Yes |
| Electrical | |||
| Power supply | 230 V AC, 5 A max | 230 V AC, 5 A max | 230 V AC, 5 A max |
| Copper output | 24 V, 2 A max (shared) | 48 V, 3 A max | 48 V, 9.5 A max |
| Silver output | 24 V, 2 A max (shared) | 12 V, 0.9 A max | 12 V, 2.5 A max |
| Physical | |||
| Main unit, L × W × H | 432 × 130 × 141 mm | 1040 × 190 × 125 mm | 1558 × 272 × 208 mm |
| Control panel, H × W × D | Compact control box | 500 × 400 × 200 mm | 500 × 400 × 200 mm |
| Weight | 2 kg | 8 kg + 12.5 kg panel | 17 kg + 12.5 kg panel |
| Application | |||
| Designed for | Low flow. A flow switch gives precise dosing at low flows. | Site-wide treatment. Ultrasonic measurement doses down to parts per billion. | Very high flow, for large buildings and campuses. |
| Typical sites | Schools, food preparation, hospital wards, swimming pools | Hotels, offices, leisure and sports centres, mid-sized hospitals | Large hospitals, universities, airports, industrial sites |
Dimensions in mm
Product launch recap.
Why copper and silver. And why Ray.
Good distribution
Treats the whole system, not just the point of contact. Breaks down biofilm.
Non-corrosive
Won’t corrode your pipework.
Highly effective
Eradicates bacteria to make water clean and risk-free.
Residual efficacy
Long lasting efficacy. Great for stagnant water.
Scientifically proven to work
Hundreds of sites and hundreds of papers prove its efficacy.
Environmentally friendly
Reduces chemical usage, minimising environmental impact.
Safe and hazard free
Safe to consume and handle. No COSHH issues.
Effective at any water temperature
Won’t ‘gas off’ at high temperatures. Great if you struggle to maintain hot water.
Cost effective
Lowers maintenance costs by minimising additional treatment needs.
How copper and silver ionisation compares. Against the main Legionella control methods.
| Parameter | Copper & silver ionisation |
Temperature regime |
Chlorine dioxide |
Hyper- chlorination |
UV |
|---|---|---|---|---|---|
| Residual effect | Prolonged | None | Decays at hot temps | Yes | None |
| Effect on biofilm | Controls | None | Penetrates 100µm only | Limited | Point of entry only |
| Affected by temperature | Unaffected | — | Decays when hot | Compromised | Unaffected |
| Recolonisation after shutdown | 6–12 weeks | Not known | 4 days | Days | — |
| Adverse effects | Staining in hard water | Scalding, corrosion | Hazardous, corrosive | THMs, highly corrosive | None known |
| Protects whole system | Yes | No | Yes | Yes | No |
EffectivePartialPoor or hazardousNot applicable
Summarised from published research.
From the flow to every outlet.
- 01 · Water
Water enters the chamber.
Water flows through the Ray unit on its way into the building.
- 02 · Electrodes
Copper and silver in the flow.
Copper and silver bars sit directly in the water path.
- 03 · Charge
A low DC current is applied.
The control sets the current to match the flow.
- 04 · Ions
Ions are released into the water.
Copper and silver ions mix evenly with the flow.
- 05 · Contact
Ions break the cell wall.
They weaken bacteria and break down biofilm.
- 06 · Residual
Protection stays downstream.
Ions travel with the water to every outlet in the system.
Case studies. Real buildings.
Explore real-world examples of our copper silver ionisation technology delivering compliance and safety in complex water systems.
Read Case StudiesBecome a Ray reseller. Your clients. Our expertise.
Add Ray copper and silver ionisation to your water hygiene services. Offer systems for low, mid and high flow, and build ongoing service revenue around every sale.
Reseller pricing
A capital discount on every Ray system, rising as your volume grows.
Recurring service revenue
Build maintenance, consumables and water sampling into your hygiene contracts.
Engineer training
We train your engineers to install and maintain Ray systems themselves.
Sales and technical support
Site suitability checks, co-branded materials and case studies for your proposals.
Request more information. We'll come back to you.
Tell us what you need and the right person will reply.
Prefer to talk? Call +44 (0)1525 854 111 or email sales@proeconomy.com